[. . . ] Cold, CW: cold mains water, the type of water used in a specific phase of the program. Hot, HW: hot mains water, the type of water used in a specific phase of the program. [. . . ] The efficacy of the thermal disinfection process is indicated by means of parameter A0. In preset programs, the target value for a thermal disinfection process is always at least 80°C. The temperature inside the tank is kept constant around the specified value for the time shown in the table. The phase during which the temperature is held at the target value is called the EXTENSION phase. When no target temperature is indicated or the indication is (“0”), the heating elements are not activated (e. g. during a cold prewash or for cold rinses). 19 592 0349 04 GW6010 – GW7010 – PROGRAM TABLE 1 VARIOUS NOTES WATER FILLING: at each step corresponds a load equal to 23 liters of water. ATTENTION: The editing of a washing program requires specific knowledge in relation to the load-treatment process, and to the device parameters. Always proceed according to the rules in force in the place of installation: a custom program, used to process the load, must be validated according to the standards and regulations applicable. Warning: when creating a custom program, do not include more than two thermal disinfection phases at 93°C for 10min. 19 592 0349 04 GW6010 – GW7010 – PROGRAM TABLE 2 LABORATORY – PROGRAM TABLE Prewashing / Washing / NAOH washing Washing / NAOH washing / Thermo disinfection Neutralization Mains rinsing Demi rinsing Rins. Demi hot Drying phase ID_prog H2O load H2O load H2O load H2O load H2O load H2O load Temp °C Temp °C Temp °C Temp °C Temp °C Temp °C Laboratory programs 1 2 3 4 5 6 7 8 9 10 1 Prewash GW 2 Plastic 3 Glassware - quick 4 Glassware - med. 7 Glassware (blood) 8 Glassware AGAR 9 AGAR Intensive Cold Cold 0 0 5 3 P1 Hot P1 Hot P1 Hot P1 80 90 93 93 93 P4 93 93 93 93 93 P4 93 P4 93 P4 93 P4 10 1 5 3 10 5 10 1 5 3 3 3 5 75 5 75 3 Cold 75 3 Hot P2 Hot P2 Hot P2 Hot P2 Hot P1 Cold P1 Hot P1 Hot P1 P1 Hot P1 P3 Hot Hot P2a Hot P2 Hot P2 Hot P2 Hot P2 Hot P2 Cold P1 Cold P1 Hot P1 P3 Hot P1 P3 Hot P1 P3 Hot P1 P3 Hot P2 Hot P2 Hot P2 Hot P2 Hot P2 Hot P2 NC 2 Hot NC 2 Demi NC 1 Demi 75 1 100 30 NC 2 Hot NC 2 Demi NC 1 Demi 75 1 100 30 NC 2 Hot NC 2 Demi NC 1 Demi 75 1 100 30 NC 2 Hot NC 2 Demi NC 1 Demi 75 1 100 30 NC 2 Hot NC 2 Demi NC 1 Demi 75 1 100 30 NC 2 Hot NC 2 Demi NC 1 Demi 75 1 100 30 NC 2 Demi NC 2 Demi 75 1 100 30 NC 2 Demi NC 2 Demi 75 1 100 30 NC 2 Hot NC 1 Demi NC 2 Demi 75 1 100 30 NC 3 Hot NC 1 Demi NC 2 Demi 75 1 100 30 NC 3 Hot NC 1 Demi NC 2 Demi 75 1 100 30 NC 2 Hot NC 1 Demi NC 2 Demi 75 1 100 30 NC 2 Hot NC 1 Demi NC 1 Demi 75 1 90 30 NC 2 Demi NC 1 Demi 75 1 80 30 NC 2 Demi NC 1 Demi 75 1 80 30 NC 3 Hot NC 1 Demi NC 1 Demi 75 1 80 30 1800 3600 3600 6000 3600 12000 6000 12000 1200 6000 1200 12000 Hot P1 Cold P1 Hot P1 Hot P1 P3 P4 NC 3 3 NC 80 3 3 10 Thermal disin. 16 16 Oil grease 17 17 Mineral Oil Cold P1 Cold P1 Hot Hot P1b Hot P1 P1 P3 Hot P3 P4 P4 NC NC NC NC 50 75 2 2 2 2 2 1 19 592 0349 04 GW6010 – GW7010 – PROGRAM TABLE 3 Cycle time std [min] 10 90 70 73 80 88 96 88 96 80 84 97 101 83 89 94 107 Temperature °C Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) Extension (min) A0 Prewashing / Washing / NAOH washing Washing / NAOH washing / Thermo disinfection Neutralization Mains rinsing Demi rinsing Rins. [. . . ] - Program “202 Service 1” It performs a loading of all installed peristaltic pumps - can be used to fill the circuit of detergents in case of first installation or to check the proper functioning of the peristaltic (detergents) pumps. - Program "203 Probes calibration" to verify the good calibration of temperature probes in chamber. [. . . ]